  99 1-800-526-2324 ? www.us.tdk-lambda.com/lp/ disclaimer: us.tdk-lambda.com/lp/legal.htm SWS300/600 series features u low cost u active power factor correction u universal input (85 - 265vac) u input transient protected iec61000-4 u semi f47 certi? ed (208vac input) u global safety approvals u level b emi single output general purpose power supplies model SWS300 sws600 input voltage range (1) - 85 - 265vac (47 - 63hz) or 120 - 370vdc inrush current (115 / 230vac) a 20 / 40 at 25c, cold start power factor - meets en61000-3-2 input current (100/200vac) a 3.6 / 1.8a 7.2 / 3.6a temperature coef? cient - <0.02%/c overcurrent protection - >105%, constant current style overvoltage protection v 3.3v: 4.1-5.3v, 5v: 6.25-7.5v, 12v: 13.8-16.8v 15v: 19.3-24.2v, 24v: 30-34.8v, 36v: 41.4-50.4v, 48v: 60-69.6v overtemperature protection - yes, cycle ac to reset hold up time (typ) ms 20ms at 115/230vac leakage current (max) ma SWS300: 0.75ma , sws600: 1.5ma remote sense - none yes parallel connection - none yes remote on/off - none yes, >4.5v to shutdown power fail signal - none yes, open collector output led indicator - green led = on operating temperature c -10 to +65c (see table for derating - model speci? c) storage temperature c -30 to +85c humidity (non-condensing) - 30 - 90% rh operating, 10 - 95%rh non operating cooling - internal fan withstand voltage - i/p to grnd 2kvac, i/p to o/p 3kvac, o/p to grnd 500vac, o/p to cnt 100vac for 1 min isolation resistance - >100m at 25c & 70%rh, output to ground 500vdc vibration (non operating) - 10 - 55hz (sweep for 1 min)19.6m/s 2 constant x, y, z 1 hour each plane) immunity - en61000-4-2, -3, -4, -5, -6, -8, -11 safety agency approvals - ul60950-1, csa60950-1, en60950-1, en50178, ce mark, semi f47 (208vac) conducted & radiated emi - en55011 / en55022-b, fcc class b recommended emi filter - mc1206 mc1210 weight (typ) g 950 2000 size (wxhxd) in 2.05 x 4.01 x 7.8 3.62 x 4.72 x 7.48 warranty yrs two years notes: (1) derate linearly to 80% load from 115vac to 85vac input (derate to 90% load for sws600-5, no derating SWS300, 600-3) speci? cations key market segments & applications free datasheet http://www.datasheet-pdf.com/
100 1-800-526-2324 ? www.us.tdk-lambda.com/lp/ revision a9: dec 2011 SWS300/600 series for additional information, please visit us.tdk-lambda.com/lp/products/sws-series.htm outline drawing SWS300 outline drawing see note "c" (tapped at the bottom chassis) (tapped on both sides) see note "c" see note "c" (tapped on both sides) name plate hole at the opposite chassis + + + name plate 150?0.5 70?0.5 120?1 7-m3.5 92?1 8-m4 50?0.5 21 (21) (25) 25 (20) 20 10 100?0.5 190?1 (10) (20) 150?0.5 20 5max air flow 21 34 11 9.5 21max 15max (72) 7.5 10 (73) (16.5) 9.0 8.2 ( ) tog pc pf cnt n l ac -s +s - - h v.adj on input: 100-240vac ~ 4.4a n h +v +v+v -v -v -v l 50/60hz made in china bar code output: 5 v 55 a SWS300- 5 v adj hws 15-1500w single output, high reliability sws 50-150w single output zws 5-240w pcb style single output notes: (2) peak rating of 120a for 10s (3) 115/230vac other industrial products max load line ripple adjust curr. reg reg noise eff.(3) model voltage range (a) (mv) (mv) (mv) (typ)% SWS300-3 3.3v 2.97-3.96v 55 40 20 120 67/70 SWS300-5 5v 4.5-6v 55 40 20 120 75/78 SWS300-12 12v 9.6-13.2v 26 96 48 120 77/80 SWS300-15 15v 13.2-18.6v 21 120 48 120 79/83 SWS300-24 24v 20-28.8v 13 120 48 150 80/84 SWS300-36 36v 28.8-40v 8.7 180 72 200 82/85 SWS300-48 48v 40-57.6v 6.7 240 96 240 82/85 sws600-3 3.3v 2.97-3.96v 100 (2) 40 20 100 69/71 sws600-5 5v 4.5-6v 100 (2) 40 20 100 74/77 sws600-12 12v 9.6-13.2v 50 96 48 120 78/81 sws600-15 15v 13.2-18.6v 40 120 48 120 80/83 sws600-24 24v 20-28.8v 25 120 48 150 81/84 sws600-36 36v 28.8-40v 16.7 180 72 200 81/85 sws600-48 48v 40-57.6v 12.5 240 96 240 82/85 model 50c 55c 60c 65c SWS300 100% 91.6% 83.3% 50% sws600 100% 85% 70% 55% additional derating required when operating sws600 with side ventilation holes blocked - see installation manual. suf? x descriptor /co2 double sided conformal coating model selector derating options free datasheet http://www.datasheet-pdf.com/


▲Up To Search▲   

 
Price & Availability of SWS300

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X